Biosensor
biosensor
Development of an Optical and Colorimetric Biosensor for the Quantification of Microrna 184 for Late Life Depression
Personalized medicine and predictive health and wellness: Adding the chemical component
Wearable sensors that detect and quantify biomarkers in retrievable biofluids (e.g., interstitial fluid, sweat, tears) provide information on human dynamic physiological and psychological states. This information can transform health and wellness by providing actionable feedback. Due to outdated and insufficiently sensitive technologies, current on-body sensing systems have capabilities limited to pH, and a few high-concentration electrolytes, metabolites, and nutrients. As such, wearable sensing systems cannot detect key low-concentration biomarkers indicative of stress, inflammation, metabolic, and reproductive status. We are revolutionizing sensing. Our electronic biosensors detect virtually any signaling molecule or metabolite at ultra-low levels. We have monitored serotonin, dopamine, cortisol, phenylalanine, estradiol, progesterone, and glucose in blood, sweat, interstitial fluid, and tears. The sensors are based on modern nanoscale semiconductor transistors that are straightforwardly scalable for manufacturing. We are developing sensors for >40 biomarkers for personalized continuous monitoring (e.g., smartwatch, wearable patch) that will provide feedback for treating chronic health conditions (e.g., perimenopause, stress disorders, phenylketonuria). Moreover, our sensors will enable female fertility monitoring and the adoption of more healthy lifestyles to prevent disease and improve physical and cognitive performance.
A modular, free and open source graphical interface for visualizing and processing electrophysiological signals in real-time
Portable biosensors become more popular every year. In this context, I propose NeuriGUI, a modular and cross-platform graphical interface that connects to those biosensors for real-time processing, exploring and storing of electrophysiological signals. The NeuriGUI acts as a common entry point in brain-computer interfaces, making it possible to plug in downstream third-party applications for real-time analysis of the incoming signal. NeuriGUI is 100% free and open source.
Electrophysiologic Monitoring and Modulation of Enteric Nervous System
We will highlight recent technological and methodological advances in deploying miniaturized technologies that can monitor the spatial electrophysiologic patterns of the visceral nervous system. As an example, we will discuss recent developments of thin, stretchable, wireless biosensor patches that can be embedded within routinely used medical adhesives for recording electrophysiologic patterns of the GI tract. We will also showcase recent developments in array signal processing that enable non-invasive tracking, and source localization, of the slow wave patterns associated with the GI tract. We will illustrate how such systems can also be used in tandem with novel miniaturized pacing devices to can enable closed-loop neuromodulation of the enteric nervous system. We will conclude with a summary of the knowns and unknowns in how multi-organ physiology research, technology miniaturization, and data science may create unique opportunities for the intersection of electrical engineering and neuroscience.
Multiphoton imaging with next-generation indicators
Two-photon (2P) in vivo functional imaging of genetically encoded fluorescent Ca2+indicators (GECIs) for neuronal activity has become a broadly applied standard tool in modern neuroscience, because it allows simultaneous imaging of the activity of many neurons at high spatial resolution within living animals. Unfortunately, the most commonly used light-sources – tunable femtosecond pulsed ti:sapphire lasers – can be prohibitively expensive for many labs and fall short of delivering sufficient powers for some new ultra-fast 2P microscopy modalities. Inexpensive homebuilt or industrial light sources such as Ytterbium fiber lasers (YbFLs) show great promise to overcome these limitations as they are becoming widely available at costs orders of magnitude lower and power outputs of up to many times higher than conventional ti:sapphire lasers. However, these lasers are typically bound to emitting a single wavelength (i.e., not tunable) centered around 1020-1060 nm, which fails to efficiently excite state of the art green GECIs such as jGCaMP7 or 8. To this end, we designed and characterized spectral variants (yellow CaMP = YCaMP) of the ultrasensitive genetically encoded calcium indicator jGCaMP7, that allows for efficient 2P-excitation at wavelengths above 1010nm. In this talk I will give a brief overview over some of the reasons why using a fiber laser for 2P excitation might be right for you. I will talk about the development of jYCaMP and some exciting new experimental avenues that it has opened while touching on the prospect that shifting biosensors yellow could have for the 2P imaging community. Please join me for an interesting and fun discussion on whether “yellow is the new green” after the talk!
Nanobody-based FRET biosensors to quantify endogenous group I metabotropic glutamate receptors
FENS Forum 2024